A well plate pipetting tracker for the bench. Tap each well as you load it, run several reagents as colored rounds, and never lose your place on a 96 or 384 well plate.
TAP → TRACK → PASS
| Space | Mark next (well, row or column) |
| ← ↑ → ↓ | Move next · A back to auto |
| Z | Undo |
| W / R / C | Work by well / row / column |
| S | Switch between add and skip |
| Enter | Round done, next round |
| 1–8 | Switch round |
| Shift + click | Fill a rectangle from the last well |
In 1:1 mode the plate is drawn at real size, from the SLAS/ANSI microplate standard, so a plate set on the iPad lines up with the wells on screen. Calibrate once against the plate's edges or a bank card (85.60 × 53.98 mm).
| SLAS/ANSI microplate | 96-well | 384-well |
|---|---|---|
| Footprint | 127.76 × 85.48 mm | 127.76 × 85.48 mm |
| Well spacing (pitch) | 9.0 mm | 4.5 mm |
| A1 centre from left edge | 14.38 mm | 12.13 mm |
| A1 centre from top edge | 11.24 mm | 8.99 mm |
| Wells | 8 rows × 12 columns | 16 rows × 24 columns |
Example. Four reagents into every well of a 96-well plate is 384 single-channel additions — four rounds of 96 taps, each round turning PASS ✓ when its last well is in. With an 8-channel pipette in COLUMN mode, each round is 12 taps, so the whole plate is 48. Wells you leave out of a round (blanks) are marked SKIP and don't hold up the PASS.
LAST UPDATED · HOW VALUES ARE CHECKED · ABOUT LABMATE.TOOLS
Yes. Switch to ROW or COLUMN and a single tap — or MARK NEXT — marks the whole row or column at once.
No. Progress is saved in your browser after every tap, so a refresh or a closed tab keeps your plate. Private browsing, clearing site data, or switching device or browser starts a fresh plate.
Yes. Choose 1:1 and calibrate once against the plate's edges or a bank card. The plate is then drawn at its real size, using the standard SLAS/ANSI footprint and well positions.
Each reagent is a round — up to 8 per plate. Mark wells as added or skipped; when every well is in, the round shows PASS and you move to the next one.
Yes. Pick 384 at the top. Up to 12 plates per format and 8 rounds (reagents) per plate are kept in your browser.
In 1:1 mode, yes: it is drawn to the SLAS/ANSI microplate standard (127.76 × 85.48 mm, 9 mm well pitch for 96-well) after a one-time calibration, so a plate set on an iPad lines up with the wells.
The ROUND LOG keeps the time each round reached PASS; COPY LOG pastes the plate, rounds and times into your notebook.
1:1 mode draws the plate at its real size, so a 96 or 384 well plate sits right on the iPad and the highlighted wells light up under the real ones. The first time takes a one-minute calibration.