labmatetools / 1.1 PLATE TRACKER
ROUND 1 / 1 Reagent 1
NEXT WELL A1
SECTION 01 — PLATES · 1.1
FIG. 1.1

Plate Tracker

A well plate pipetting tracker for the bench. Tap each well as you load it, run several reagents as colored rounds, and never lose your place on a 96 or 384 well plate.

TAP → TRACK → PASS

How to use

  1. Pick 96 or 384 at the top. Working on several plates? + NEW under PLATES adds one (up to 12 per format); tap a plate to switch, each keeps its own rounds.
  2. Name the round after the reagent you are adding — tap its name in the list to edit.
  3. On an iPad you can set the plate right on the screen: choose 1:1, calibrate once against the plate's edges (or a bank card), and the plate is drawn at its real size — standard SLAS/ANSI footprint and well positions.
  4. Tap a well as you pipette into it, or press the big MARK NEXT button to fill in order (by column or by row).
  5. Plate lined up on the iPad screen? Use the MOVE NEXT arrows to put the next well, row or column exactly where you are. After that, MARK NEXT carries on from there. AUTO returns to the first open spot.
  6. Using a multichannel? Switch to ROW or COLUMN: a tap, or MARK NEXT, then marks the whole line at once.
  7. Blanks or wells that don't get this reagent: switch ADD to SKIP, then tap them or use SKIP NEXT — a well, row or column at a time. In a round a well is either added or skipped: wells already added stay added. Skipped wells are left out of the count, and a new round starts with the same wells skipped.
  8. When every well is in, the round shows PASS ✓. Go to the next round — up to 8 per plate. The ROUND LOG keeps the time each round passed; COPY LOG pastes it into your notebook.
  9. Laid the plate out in Plate Layout first? Use TRACK IN PLATE TRACKER there: empty wells come in skipped, and the next well shows its sample name.

Keyboard

SpaceMark next (well, row or column)
← ↑ → ↓Move next · A back to auto
ZUndo
W / R / CWork by well / row / column
SSwitch between add and skip
EnterRound done, next round
1–8Switch round
Shift + clickFill a rectangle from the last well

Good to know

  1. Free to use. No subscription.
  2. Progress is saved in this browser after every tap, so a refresh or a closed tab won't lose your plate. Private browsing, clearing site data, or switching device or browser starts a fresh plate.
  3. Built for iPad at the bench; works on a laptop and a phone too.
  4. A tracker, not a record: it does not replace your lab notebook or LIMS. The round log is a convenience copy.
REFERENCE · PLATE TRACKER

Plate geometry used for the 1:1 view

In 1:1 mode the plate is drawn at real size, from the SLAS/ANSI microplate standard, so a plate set on the iPad lines up with the wells on screen. Calibrate once against the plate's edges or a bank card (85.60 × 53.98 mm).

SLAS/ANSI microplate96-well384-well
Footprint127.76 × 85.48 mm127.76 × 85.48 mm
Well spacing (pitch)9.0 mm4.5 mm
A1 centre from left edge14.38 mm12.13 mm
A1 centre from top edge11.24 mm8.99 mm
Wells8 rows × 12 columns16 rows × 24 columns

Worked example

Example. Four reagents into every well of a 96-well plate is 384 single-channel additions — four rounds of 96 taps, each round turning PASS ✓ when its last well is in. With an 8-channel pipette in COLUMN mode, each round is 12 taps, so the whole plate is 48. Wells you leave out of a round (blanks) are marked SKIP and don't hold up the PASS.

LAST UPDATED · HOW VALUES ARE CHECKED · ABOUT LABMATE.TOOLS

QUESTIONS · PLATE TRACKER

Frequently asked

Can I use the plate tracker with a multichannel pipette?

Yes. Switch to ROW or COLUMN and a single tap — or MARK NEXT — marks the whole row or column at once.

Will I lose my place if the page refreshes?

No. Progress is saved in your browser after every tap, so a refresh or a closed tab keeps your plate. Private browsing, clearing site data, or switching device or browser starts a fresh plate.

Can I set the plate directly on my iPad screen?

Yes. Choose 1:1 and calibrate once against the plate's edges or a bank card. The plate is then drawn at its real size, using the standard SLAS/ANSI footprint and well positions.

How do I track several reagents on the same plate?

Each reagent is a round — up to 8 per plate. Mark wells as added or skipped; when every well is in, the round shows PASS and you move to the next one.

Does it work for 384-well plates?

Yes. Pick 384 at the top. Up to 12 plates per format and 8 rounds (reagents) per plate are kept in your browser.

Is the plate on screen the real size?

In 1:1 mode, yes: it is drawn to the SLAS/ANSI microplate standard (127.76 × 85.48 mm, 9 mm well pitch for 96-well) after a one-time calibration, so a plate set on an iPad lines up with the wells.

Can I record when each reagent was added?

The ROUND LOG keeps the time each round reached PASS; COPY LOG pastes the plate, rounds and times into your notebook.